High Quality MRI Magnetic Resonance Imaging Scanning Machine

Product Details
Customization: Available
Origin: China
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485
Export Year
2015-07-21
  • High Quality MRI Magnetic Resonance Imaging Scanning Machine
  • High Quality MRI Magnetic Resonance Imaging Scanning Machine
  • High Quality MRI Magnetic Resonance Imaging Scanning Machine
  • High Quality MRI Magnetic Resonance Imaging Scanning Machine
Find Similar Products

Product Description

MRI Scanning System Magnetic Resonance Imaging System MRI Scanner Machine 


High Quality MRI Magnetic Resonance Imaging Scanning Machine

High Quality MRI Magnetic Resonance Imaging Scanning Machine

No. Item Specification
1 Magnet System  
1.1 Magnet Type Permanent magnet with automatic constant  temperature system
1.2 Field strength 0.35T
1.3 Magnet shape C-shape
1.4 Homogeneity (40cm, DSV, VRMS) ≤2.5ppm
1.5 Shim method Active/Passive/Dynamic
1.6 Magnet vertical gap 40cm
1.7 Accessibility (Horizontal opening angle) >270°
1.8 5 Gauss fringe field 2.5m*2.5m*2.5m
2 Gradient System  
2.1 Gradient field strength (Single Axis) 25mT/m
2.2 Gradient slew rate (Single Axis) 75mT/m/ms
2.3 Rise time 0.3ms
2.4 Gradient cooling system(Gradient coils
and power electronics)
Air
3 RF System  
3.1 Spectrometer Fully digital
3.2 RF system type Digital Transmit and Receive
3.3 Number of RF channel 4
3.4 Transmitter amplifier peak power 6kW
3.5 RF bandwidth of receiver Each 400KHz
3.6 Dynamic range ≥80dB
3.7 Noise factor 0.3dB
3.8 Coil type Phase array
3.9 Head coil Available
3.10 Neck coil Available
3.11 Body coil (small) Available
3.12 Body coil (large) Available
3.13 Knee coil Available
3.14 Ankle coil Available
3.15 Shoulder coil Available
3.16 Soft coil Available
3.17 Breast coil Available
3.18 Wrist coil Available
  Remark: The coil configuration is subject to the final contract  
4 Patient communication  
4.1 Max. patient weight 200Kg
4.2 High accurate position assist Yes
4.3 Localizer Yes
4.4 Position accurate ≤1mm
4.5 Position accessories Yes
4.6 Emergence call Yes
4.7 Communication system Yes
5 Computer system  
5.1 Host computer Dual core
5.2 System software BASDA
5.3 OS WINDOWS 7
5.4 CPU clock rate ≥2.8GHz, be able for extension
5.5 Main memory ≥2GB, be able for extension
5.6 Color LCD monitor 24"
5.7 Keyboard and mouse Standard
5.8 Hard disk ≥250GB, be able for extension
5.9 Media driver CRW / DVD
5.10 DICOM 3.0 Yes
5.11 Ethernet Yes
6 Scanning parameter  
6.1 Max. FOV 400mm
6.2 Min. FOV 20mm
6.3 Min. 2D Thickness 1mm
6.4 Min. 3D thickness 0.1mm
6.5 Max. Image matrix 1024*1024
7 Scanning sequence &imaging technology  
7.1 Spin echo 2D/3D (SE 2D/3D) Yes
7.2 Multi-slice multi-echo(MSME) Yes
7.3 Gradient echo(GRE 2D/3D) Yes
7.4 Steady state process gradient echo( SSPGRE) Yes
7.5 Fast spin echo (FSE) Yes
7.6 Fast double echo(FDE) Yes
7.7 Fast recover fast spin echo(FRFSE) Yes
7.8 Single shot fast spin echo(SSFSE) Yes
7.9 Multi shot fast spin echo (MSFSE) Yes
7.10 Inversion recovery (IR) Yes
7.11 Inversion recovery fast spin echo (IRFSE) Yes
7.12 Short time inversion recovery (STIR) Yes
7.13 Fluid attenuated inversion recovery(FLAIR) Yes
7.14 Gating technology Yes
7.15 Breath holding scan Yes
7.16 TOF 2D MRA Yes
7.17 TOF 3D MRA Yes
7.18 Diffusion weighted imaging (DWI) Yes
7.19 Max. b Value 1000s/mm2
7.20 Magnetization transfer (MTC) technology Yes
7.21 MIP Yes
7.22 MinIP Yes
7.23 3D position Yes
7.24 Pre-saturation technology (PS) Yes
7.25 Pre-saturation adjustment technology Yes
7.26 Part metal implant scan technology Yes
7.27 Automatic coil tuning Yes
7.28 MRM Yes
7.29 MRU Yes
7.30 MRCP Yes
7.31 Online image filtration Yes
7.32 Online post procession Yes
7.33 Optimal algorithm of active shimming Yes
7.34 Scan sequence queuing Yes
7.35 Multi-layer and multi-angle scanning technology Yes
7.36 Optimize bandwidth acquisition technology Yes
7.37 Flow compensation Yes
7.38 Parallel acquisition technology Yes
7.39 Section acquisition technology Yes
7.40 Scan parameter preset Yes
7.41 Oversampling technology Yes
7.42 Image fusion technology Yes
7.43 Artifact suppression technology (K_Rotat) Yes
7.44 Thin imaging technology Yes
7.45 Movie playback technology Yes
7.46 Post processing package Yes