• 17 Inch Multi-Parameter Medical Portable Patient Monitor

17 Inch Multi-Parameter Medical Portable Patient Monitor

Feature: Reusable
Application: Clinical
Material: Plastic
Power Type: Electric
Group: Adult
Screen: 17 Inches TFT Screen of LCD
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Basic Info.

Model NO.
MC-C90
Transport Package
Standard for Export
Specification
400mm× 180mm× 380mm
Trademark
Mecan
Origin
China
HS Code
90181930
Production Capacity
in Stock

Product Description

17 Inch Multi-Parameter Medical Portable Patient Monitor
 
Standard Configuration:
5-lead ECG, RESP, Dual-Temp, Comen SpO2,
NIBP, EtCO2 (Without sensor)
Optional:
Masimo/Nellcor SpO2, Dual-IBP, AG, C.O., BIS,
3/12-lead ECG, Suntech NIBP, EtCO2, Thermal Recorder, ICG, Trolley, Wall mount, Ground wire
Safety Standards
MDD 2007/47/EC, EN ISO13485, EN 60601-1, EN 60601-1-2, EN 980, EN 1041, EN 12470-4, EN 60601-2-27, EN 60601-2-30, EN 60601-2-34, EN 60601-2-49, EN 60601-1-8,
EN ISO 10993-1, EN ISO 10993-5, EN ISO 21647, ISO 9919, EN 1060-1, EN 1060-3, EN 62304, EN 62366, EN 60601-1-6, EN 60601-2-26, EN ISO 14791, EN 1060-4, EN60601-1-4
Physical Characteristics
Size: 400mm×180mm×380mm
Weight 10 kg
Screen Size: 17.1" TFT touch screen
Resolution 1280 × 1024
IP grade IPX1
Waveforms: up to 10 waveforms
Operation Environment
Temperature: 5-40ºC
Humidity: 93%
Power requirement: 100-240V~, 50/60Hz
Battery Type:  Rechargeable Lithium-ion battery
Battery Capacity: 4400mAh
Battery Recharging Time:
Maximum 6 hours for charging;
Battery backup: 4 hours for continuous working
Date storage  
Alarm Event Recall:
200 groups
Wave Recall: 6 hours (8 waves)
NIBP Recall: 2000 groups
Trend Graph: 160hours
Trend Table: 160hours



ARR Event:



100 groups
Interfacing
  USB interface
  RJ45 network interface
  Plug-in slot
  Multi-functional connector
Recorder  
Type: Built-in; Thermal array
Channel: 3 channel waveforms
Speed: 25mm/s,50mm/s
Record width: 50mm
Real-time record time
8s, 16s, 32s or continual
Alarm record Yes
Respiration  
Method: RA-LL Impedance Method
RR measurement range:
Adult: 0-120rpm 
Pediatric/Neonate: 0 -150bpm 
Accuracy: 7-150rpm: ±2rpm or ±2% (whichever is greater)
0-6rpm: unspecified
RESP Apnea Adult: 10s-60s Ped/Neo: 10s~40s
Accuracy: 5s
Alarm:
Sweep Speed:
Gain Selection:
 
Audible and visual alarm; alarm events reviewable
6.25,12.5, 25 mm/s
X0.25, X0.5, X1, X2, x4

 