ICU Invasive Ventilator with Compressor

Product Details
Customization: Available
Customized: Non-Customized
Scale: Large
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485
Export Year
2015-07-21
  • ICU Invasive Ventilator with Compressor
Find Similar Products

Basic Info.

Model NO.
MCA-VH1
Type
Ventilator
Transport Package
Standard for Export
Trademark
Mecan
Origin
China
Production Capacity
50 Units for 15 Working Days

Product Description

ICU Ventilator with Compressor

Model:MCA-VH1

MCA-VH1 can be used in respiratory management of after anesthesia operation, ambulance room, ICU, etc.

Specification:
Ventilator MCA-VH1 has volume control and pressure control working modes. The transduction from inspiration to expiration can be realized by setting the value of time, pressure, volume, and flow rate. Its preset TV range is 50-1500ml, Frequency is 2-60bpm, and flow rate is 10-120L/min. It can be applied to adult and pediatrics.

Ventilator MCA-VH1 can provide respiration modes include:A/C, SIMV, PCV, PSV, MMV, and SIGH. It also has PEEP support function. It can realize extra respiratory modes like CPAP, SIMV+PSV, inverse ration ventilation through combination of respiratory modes and setting parameters.

Ventilator MCA-VH1 provides the following alarms: TV upper/lower limit, peek pressure upper/lower limit, frequency upper/lower limit, MV upper/lower limit, oxygen concentration upper/lower limit, PEEP upper /lower limit, apnea, AC power cutoff. When power cutoff, the built-in battery will be drive the ventilator work.

Parameters:

A/C mode      Other parameters:  
1. Oxygen concentration:          21~100% 1. Oxygen pressure: 50.75~79.75 psi
2. PEEP pressure:               0~20 cmH2O 2. Noice  <65 dBA
3. Tidal volume:                  50~1500 ml 3. Environment:  
4. Frequency:                  2~60 bpm Temperature: 5ºC~ 40ºC
5. I:E ratio:                      3.0:1~1:3.0 Relative humidity ≤85%(25ºC)
6. Waveform:  square waveform, speed-down waveform Gas pressure: 960~1060 cmH2O
7. Inspiratory platform:            0~50%        4. Power: A/C160~242V,50±1Hz
8. Inspiration sensitivity:   -1~-20 or (OFF)cmH2O 5. Power consumption: 40VA
9. SIGH:                       1.0~2.0 VT/50    
    Monitor parameters  
SIMV mode   1.TV: 0~9999 mL
1. Oxygen concentration:          21~100% 2. Respiratory frequency: 0~100 bpm
2. PEEP pressure:  0~20 cmH2O Machine-controlled frequency: 0~100 bpm
3. Tidal volume: 50~1500 ml  Respiratory effort frequency: 0~100 bpm
4. SIMV frequency: 2~35 bpm 3. I:E ratio:  3.0:1~1:9.9
5. Spontaneous support pressure:    0~35 cmH2O 4. Expiration end pressure:                 0~65 cmH2O
6. Inspiration time: 0.2~3.0 S 5. Peak pressure 0~68 cmH2O
7. Inspiration sensitivity:   -1~ - 20 cmH2O 6. MV: 0~99.9 L/min
8. Flow rate ascending speed:       10~400  L/min/S 7.Machine-controlled MV: 0~99.9 L/min
9. Expiration sensitivity:  10 -75% Respiratory effort MV: 0~99.9 L/min
10. Max. time of inspiration time:     1.0~6.0 S 7. Oxygen concentration 21~100 %
11. Apnea time: 3~12 S 8. inspiratory pressure:             0~65 cmH2O
       
PCV mode   Alarm parameters  
1. Oxygen concentration:         21~100%  1. TV upper limit: 100~2000 ml
2. PEEP pressure: 0~20 cmH2O 2. TV lower limit: 20~2000 ml
3. Frequency  2~60  bpm 3. Frequency upper limit:  5~100 bpm
4. Inspiratory pressure: 0~35 cmH2O 4. Frequency lower limit:              2~60 bpm
5. I:E ratio:  3.0:1~1:3.0     5. Peak pressure upper limit:          5~30 cmH2O
6. Inspiratory platform:            0~50% 6. Peak pressure lower limit:          0~20 cmH2O
7. Inspiration sensitivity:  -1~-20 or (OFF)   cmH2O  7.Oxygen concentration upper limit: 30%~100%
8. Flow rate ascending speed:     10~400  L/min/S 8.concentration lower limit:       21%~60%
9. Min. TV:  50~1000 ml 9. MV upper limit: 4.0~40 L/min
    10. MV lower limit:  2.0~20 L/min
PSV mode   11. Apnea alarm time:  3~12 S
1.Oxygen concentration:             21~100%    
2. PEEP :   0~20 cmH2O MMV mode  
3. support pressure: 0~35 cmH2O  1. Oxygen concentration:            21~100% 
4. Inspiration sensitivity:  -1~ -20 cmH2O 2. PEEP :  0~20 cmH2O
5. Expiration sensitivity:             10~75% 3. Target TV:  50~1500 ml
6. Flow rate ascending speed:       10~400 L/min/S 4. Ventilation: 0.5~40.0 L/min
7. Min. TV: 50~1000 ml 5. Inspiration sensitivity:  -1~ -20 cmH2O
8. Max. inspiration time:  1.0~6.0 S 6. Flow rate ascending speed:        50~400 L/min/S
9. Apnea time:  3~12 S 7. Expiration sensitivity:              10~75%
10. spare frequency  5~35 bpm 8. Max. inspiration time:             

1.0~6.0 S


Medical Equipment

ICU Invasive Ventilator with Compressor

Hospital Furniture and Surgical Equipment
ICU Invasive Ventilator with Compressor

X-Ray Machine and Ultrasound ScannerICU Invasive Ventilator with Compressor

Obstetric Gyneacology Centre and Rehabilitation Therapeutic Apparatus
ICU Invasive Ventilator with Compressor

Dental Clinic Equipment and Ophthalmoscop
ICU Invasive Ventilator with Compressor

Laboratory EquipmentICU Invasive Ventilator with Compressor

Sterilizer & Disinfection ProductsICU Invasive Ventilator with Compressor

Mortuary EquipmentICU Invasive Ventilator with Compressor

Homecare ProductICU Invasive Ventilator with Compressor

Veterinary Equipment and Education EquipmentICU Invasive Ventilator with CompressorICU Invasive Ventilator with Compressor

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More