Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Display Mode: 10.4 inch High-denfinition TFT color LCD screen display
Ventilation Mode: VCV,PCV,SIMV,PSV,PSV+SIMV,CPAP
Ventilation Function: PEEP,SIGH, IRV, IP,Standby
Ventilation Parameter:
Tidal volume | 20~1800 ml |
Rate | 2~120bpm |
SIMV rate | 2~120bpm |
I:E | 4:1~1:8 |
Pressure trigger sensitivity | -10-20cmH2O |
Flow trigger sensitivity | 1-20L/min |
PEEP | 0~25 cmH2O |
Pressure range | 3~50 cmH2O |
Pressure limitation | 5~60 cmH2O |
Pressure slope | 1~10 gear |
Flow rate setting | 1~10 gear |
Expiratory trigger sensitivity | 10%-90% |
Time control | 1~10s |
SIGH | 1.5 times the inspiratory time (60-120 adjustable) |
Inspiratory platform | 0~50% |
Oxygen concentration | 21%~100% |
Oxygen concentration | Upper limit setting range | 21%-99% |
Low limit setting range | 15%-80% | |
Airway pressure alarm | Upper limit setting range | 1-60cmH2O |
Low limit setting range | 0-50cmH2O | |
Minute ventilation volume alarm | Upper limit setting range | 1-30L/min |
Low limit setting range | 0-29L/min | |
Tidal volume | Upper limit setting range | 10-2000ml |
Low limit setting range | 0-1800ml | |
Respiratory rate | Upper limit setting range | 10-99bpm |
Low limit setting range | 0-50bpm | |
Sustained high-pressure alarm | It will give alarm when stress have consistently been higher than 30 cnH2O | |
Suffocation alarm | Low pressure of Air alarm | |
Gas shortage alarm | Power alarm; Intubation off alarm | |
Low pressure of Oxygen alarm | Battery voltage alarm |
Power: AC 220V±10% 50HZ±1HZ
UPS, Storage battery
Mechanical Arms: Yes
Compressor: Yes
Package size: 69*68*145cm
Gross weight: 85kg
Production line of our ventilator