160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer

Product Details
Customization: Available
Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2011-12-26
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485
Export Year
2015-07-21
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
  • 160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Detailed Photos
  • More Product
  • Company Profile
Overview

Basic Info.

Model NO.
MCL-BA002
Group
All
Product Name
Auto Chemistry Analyzer
Sample Tray
49 Unfixed Positions for Various Samples
Reagent Tray
56 Positions
Reaction Volume
180- -500UL
Absorbency
0.000- 3.000ABS
Test Speed
160test/Hour
Reaction Time
About 10 Minutes
Transport Package
Standard for Export
Specification
750mm*520mm*600mm
Trademark
Mecan
Origin
China
HS Code
90189090
Production Capacity
Have Stock

Product Description

160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
MCL-BA002
160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
Product Description

Overall Performance
Equipment type Fully automatic discrete, STAT priority
Analysis rate Constant speed 200T/H (without ISE)
Test principle Colorimetry, turbidimetry
Analysis method End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration

Sample System
Sample Tray 42 sample positions, random access of all samples
Sample Volume 2-50ul, 0.1ul increment
Sample probe Liquid level detection, the remaining detection, collision protection etc.
Sample Containers Sample cups, Micro tube, Original blood-collection tube, etc.

Reagent System
Reagent Tray 25 reagent positions
Reagent Volume R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration 4-15ºC, independent power supply, 24-hour non-stop refrigeration

Reaction System
Reaction Tray Rotating tray, 120 cuvettes
Cuvette Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume 180-500ul
Incubation system Bi-directional liquid-air device
Temperature 37ºC±0.1ºC with real-time display

Optical System
Light source 12V35W halogen lamps, over 2000 hours
Photoelectron road after spectrophotometry
Wavelength 340,405,450,510,546,578,630,700nm
Absorbance range 0-3.500Abs
Resolution 0.0001Abs

Operating System
PC operating system Windows XP or above
Analysis control software English version graphical operating software
Report printing Report formats support the user-defined mode, QC and state information etc.
System connection RS-232

Working Conditions
Power supply AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature 15-30 ºC
Humidity 35-80%
Water consumption 5L/Hour
Dimension Bench top: 750mm*520mm*600mm
Weight 45KG

 
Specification
Test speed
160Test/Hour(without ISE)
Sample Tray
49 Unfixed Positions for various samples
Reagent Tray
56 Positions
Reaction Tray
120 High- -quality cuvettes(Optical length: 6mm)
Methodology
End-point, Kinetic, Fixed time, Nephelometer
Reaction Volume
180- -500ul
Reaction Time
About 10 minutes
Calibration Methods
Linear and Non-linear
Absorbency
0.000- 3.000Abs
Emergency Priority
Reagent Self- calefactive
Sample Consume
2ul- 50u{(0.1ul each step), with High precision Syringe
Reagent Consume
R1:25- 300ul, R2: 10-150ul, 0.1ul each step, Open for reagents
Needle cleaning
Self-wash after every step, it can reduce the across contaminated
Washing system
5 needles with 2 pumps. Self- washing in time with test.
Liquid Sensor
Self-detecting of the liquid level, tracing the rest volume
Calibration Methods
Linear and Non-linear
Wavelength
340. 405. 510. 546. 578. 600. 660.700m.+(single/Double wavelenth)
Quality Contro Test
Insert QC at any time, 6 QC types for a project
Temperature Control
37°C, Refrigeration for reagent tray(2 8C}
Light Resource
User can choose the print type by self.
Detailed Photos
160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer
160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer

 

More Product


160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer

Company Profile

160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer160 Tests/Hour Fully Automatic Biochemistry Analyzer, Clinical Chemistry Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More